JINSP Company Ltd.

JINSP Company Limited is a professional supplier with over 17 years of experience in spectral detection technology product development and manufacturing.

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Raman Gas Analyzer /

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

Contact Now
JINSP Company Ltd.
Visit Website
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MsPhoebe Yu
Contact Now

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

Ask Latest Price
Video Channel
Brand Name :JINSP
Model Number :RS2600
Certification :CE ISO9001
Place of Origin :CHINA
MOQ :1
Price :USD100000 - USD142900
Payment Terms :T/T, Western Union
Supply Ability :100PCS/90-120 days
Delivery Time :80-100 working days
Packaging Details :International Shipping Package
Laser excitation wavelength :532 ± 0.5 nm
Spectral coverage :200 ~ 4200 cm-1
Analysis time :2 seconds
Weight :40 kg
Model Name :RS2600 Multi-gas Analyzer
Metallurgical industry :N2, H2, O2, CO2, CO, etc.
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Raman Spectroscopy Multi-gas Analyzer for Simultaneous Online Analysis

JINSP® RS2600 multi-gas analyzer is based on Raman spectroscopy and can detect all gases except noble gases,enabling simultaneous online analysis of multiple gases.

It is able to detect the following multiple gases with a detection range from ppm to 100%:

  • Petrochemical industry: alkane, alkene and alkyne gases such as CH4, C2H6, C3H8, C2H4, etc.
  • Fluorine chemical industry: corrosive gases such as F2, BF3, PF5, Cl2, HCl, HF, etc.
  • Metallurgical industry: N2, H2, O2, CO2, CO, etc.

Technical Specifications:

Components

N2, H2, O2, CO, CO2, H2S, CmHn, etc.

Analysis time

2 seconds

Measurement uncertainty

≤0.2%

Laser excitation wavelength

532 ± 0.5 nm

Spectral coverage

200 ~ 4200 cm-1

Spectral resolution

≤8 cm-1 at full spectral range

Air circuit interface

6 mm standard tube fitting (3 mm, 1/8’’, and 1/4’’ are optional)

Input voltage

100~240 VAC,50~60 Hz

Sample gas temperature

-50 ~ 40 ºC

Sample gas pressure

<1.0 MPa

Unit dimensions

485 mm (Width) × 350 mm (Height) × 600 mm (Depth)

Weight

40 kg

Technical Highlights:

  • Non-destructive gas analysis: Analytes including homonuclear diatomic gases(F2, Cl2, etc.) and isotopic gases (H2, D2, T2, etc.)
  • Short detection time: Data acquired in seconds
  • Minimal maintenance: Resistance to high pressure, direct detection without consumables (chromatographic column or carrier gas)
  • Wide detection range: LOD at ppm level, detection range up to 100%

Field of Applications:

Application: 1.Monitoring of F2, N2, HF and other components in the fluorination process

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

2.Quantitative analysis of different Elements in Petrochemical Natural Gas

Effective identification and quantification of various components in natural gas mixtures within 2 seconds

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

Gas Analyzer Features:

  • Quantitative model of multiple standard curves,combined with the chemometric method, establishes the relationship between the spectral signal and the content of multi-component substances.
  • Changes in sample gas pressure and test conditions do not affect the accuracy of quantitative results.

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

Company Introduction:

JINSP Company Limited has won the National Science and Technology Commission's Scientific and Technological Achievement Appraisal Certificate and the China Patent Excellence Award, and related products have been obtained has won authoritative awards such as the Geneva International Invention Award, the Beijing New Technology and New Product Certificate, and the "Innovation Achievement Award" of the Zhu Liangyi Analytical Instrument Innovation Award.In addition, JINSP participated in the drafting of several national and international standards, including participating in the drafting of an international standard as the only participating unit in China IEC 63085 International Standard: System of spectral identification of liquids in transparent or semitransparent containers; Drafting of two national standards: GB/T 41086-2021 "General Technical Requirements for Safety Inspection Equipment for Hazardous Chemicals Based on Raman Spectroscopy", GB/T 40219-2021 "General Specification for Raman Spectrometer".

High Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 AnalysisHigh Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 AnalysisHigh Sensitivity Multi Gas Analyzer Advanced For Metallurgical Industry N2 Analysis

FAQ

Q1:This is the first time I use,is it easy to operate?

A1:We will send you manual and guide vedio in English,it can teach you how to operate the spectrometer.Also our technicians will offer professional tecnical opearation meetings.

Q2:Can you offer a operation training?
A2:Your technicians can come to our factory for a training. Jinsp technical engineers can go to your place for local support.
( installation, training,debugging,maintenance )

Q3:How to receive a best price in the shortest time?

A3:When you send us an inquiry,please kindly offer details with wavelength,detector,effective pixels,focal length and so on.We will send you quotation with details soon to your email.

Q4:If the spectrometer has problem in my place,how could I do?
A4:The spectrometer has one year warranty.If it breaks down,our technician will figure out what the problem maybe,according to client's feedback.We can repair for free within one year warranty.

Inquiry Cart 0